Page 14 - Optc Series
P. 14

FTTH Drop Cable(GJXFH-2)








                                                                                             SW905
    Optic  Series








               Introduction                                                                        LSZH jacket
              This flat drop cable, which consists of 1, 2, or 4 color coded                 FRP strength member
              optical fibers, offers an ideal solution for the smaller fiber                       Optical fiber
              counts that are needed in the final sections of an optical
              network. Two parallel FRP strength members protect the
              optical fibers. The cable is completed with a LSOH jacket.



              Cable structure and parameter                    Characteristic of Optical Cable

                 SN          Item          Unit    Value        Mechanical characteristic and test method
                  1        No. of fibers  count      2             Tensile strength    conform to IEC 60794-1-2-E1A
                  2     sheath material/color    LSZH/Black           Crush          conform to IEC 60794-1-2-E3
                  3        Fibers Color          Blue, Orange        Impact         conform to IEC 60794-1-2-E4

                  4      Strength member         FRP strength     Repeated bending    conform to IEC 60794-1-2-E6
                                                     member
                                                                     Torsion         conform to IEC 60794-1-2-E7
                  5       Cable diameter   mm       3*2
                                                                     Flexing         conform to IEC 60794-1-2-E8
                  6        Cable weight   kg/km      9
                                                                    Cable bend      conform to IEC 60794-1-2-E11
                  7      Short term tension   N     80
                                                                  Water penetration    conform to IEC 60794-1-2-F5B
                  8       Short term crush  N/100mm  1000
                                                                                     Operation    -20℃~+60℃
                Note: Mechanical sizes are nominal values.
                                                                Temperature requirement  Installation    -20℃~+60℃
                                                                                 Storage/transportation    -20℃~+60℃
                                                                Temperature cycling test  conform to IEC 794-1-F1
              G657 fiber information                                             Unloaded
                                                                                          30 times of outer diameter
               Mode field diameter (1310nm):8.6μm±9.5μm.           Bending Radius  loaded
                                                                                          60 times of outer diameter
               Cladding diameter:125μm±0.7μm.
               Coating diameter:245μm±7μm.
               Cut off wavelength of cabled fiber (  cc):≤1260μm.   Order Information
               Attenuation at 1310nm:≤0.35dB/km.
               Attenuation at 1550nm:≤0.21dB/km.                    Item        Specification  Description
               Bending loss at 1550nm (100 turns, 30mm radius):≤0.05dB.    D171  2-12  cores    Single  Mode
               Dispersion in the range 1288 to 1339nm:≤3.5ps/(nm km).
               Dispersion at 1550nm:≤18ps/(nm km).                   D172        2-12  cores     Multimode
               Dispersion slope at zero dispersion wavelength:≤0.092ps
               /(nm2 km).















                                              www.winlong-tech.com